Rotary Kiln Revamp Project

Your Partner in Cement Engineering

AGICO CEMENT / SITE SEARCH

What can we help you find?

Search equipment, replacement parts, complete plants and project cases.

Type a product name or acronym · ↑ ↓ to choose a suggestion · Esc to close

Start with a business area

DIRECT ROUTES
rotary kiln

Project details

In order to improve the output and quality of cement clinker, a factory designed a 5000t/d production line equipped with a double series five-stage cyclone preheater and a TTF type decomposition furnace. However, with increasingly stringent environmental standards, the plant underwent a denitrification retrofit in April 2018. Using staged combustion and SNCR technology, they successfully reduced nitrogen oxide emissions to below 100 mg/m³ while also controlling ammonia injection to less than 1 t/h. However, this retrofit impacted the kiln’s output and quality, with kiln production dropping from 6,100 t/d to 5,200 t/d and the clinker’s 3-day compressive strength dropping from approximately 31–32 MPa to 27–28 MPa. Facing this challenge, technicians ultimately developed an effective technical retrofit plan, successfully restoring stable output and quality.

Euiquipment configuration

1. Rotary kiln tail and waste gas treatment system

  • Preheater parameters: C1: 4-4700, C2, C3, C4, C5 are all 2-ф6800, equipped with TTF 7600×59750 decomposition furnace.
  • Kiln tail high temperature fan: air volume 820000m³/h, static pressure 7700Pa.

2. Calcination kiln body

  • ф4.8m×74m rotary kiln, slope 4%, main transmission speed range 0.4~4r/min.
  • TCNB-K55 four-channel coal injection pipe, maximum coal burning capacity 15t/h.

3. Calcination kiln head and waste gas treatment

Adopt TTFC fourth-generation grate cooler, cooling area up to 136.2m².

Analysis of Production Issues After the Staged Combustion Retrofit

After implementing the staged combustion retrofit, several production issues emerged that urgently needed to be addressed. These issues primarily included a significant decline in product quality and a certain impact on production efficiency. To deeply analyze the root causes of these issues, we need to explore them from multiple perspectives.

Rotary Kiln Output and Quality

After implementing the staged combustion modification, the rotary kiln’s output dropped significantly from 6,100 tons/day to 5,200 tons/day. Furthermore, the actual coal consumption for clinker increased from 138 kg/ton of clinker before the overhaul to 155 kg/ton of clinker after the modification, representing a significant increase in energy consumption. Furthermore, the free calcium content in the clinker product remained high. To adapt to the rotary kiln’s calcining conditions, the clinker ratio was adjusted from KH = 0.91, SM = 2.55, and IM = 1.5 to KH = 0.88, SM = 2.55, and IM = 1.5. However, this adjustment did not significantly improve the clinker quality, but instead resulted in a decrease in the 3d compressive strength from 32 MPa to 27-28 MPa. Despite attempts to improve the rotary kiln’s output and quality by adjusting operating parameters and replacing raw materials, the results were insignificant. Therefore, it is reasonable to infer that these changes are closely related to the implementation of the staged combustion modification.

Impact of the calciner system

After the implementation of staged combustion, the pulverized coal mainly burns in the cone area of the calciner. Due to the change in the air volume and wind speed at the constriction of the calciner, the calciner collapses (the material impact can be clearly felt when the chisel is inserted into the smoke chamber). This causes some raw materials that are not fully decomposed to enter the rotary kiln, thereby increasing the calcination load of the kiln and affecting the output.

Staged combustion also increases the resistance of the calciner and the constriction, thereby reducing the ventilation volume in the kiln. The opening of the tertiary air damper is also reduced from 50% before the transformation to 30%. The tertiary air volume required for the combustion of the pulverized coal fed to the calciner at the kiln tail is reduced, resulting in incomplete combustion of the pulverized coal. The CO concentration detected at the chimney at the kiln tail is as high as 2200 × 10⁻⁶, which indicates that there is a high heat loss from incomplete combustion, which will also affect the clinker output. In addition, the reduction in the opening of the tertiary air damper also increases the overall resistance of the pre-calcination system, thereby increasing the power consumption of the system.

Impact of the C4 discharge flap valve

During the discharge process at the fourth-stage lower discharge pipe, located at the precalciner cone, the material easily rushes out of the distributing box due to a height of approximately 25 meters. This results in uneven material distribution. This condition allows insufficiently decomposed material to directly enter the smoke chamber, not only affecting the decomposition efficiency but also potentially causing additional impact loads on the smoke chamber.

Kiln Outlet System

The C1 outlet temperature of the kiln outlet system is maintained at a high level of 330-340°C, accompanied by high energy consumption. When the high-temperature fan operates at 720 rpm, its inlet pressure reaches 6400 Pa, while the C1 outlet pressure is -4800 Pa, indicating significant resistance within the system.

Upgrade and Renovation Goals

  • Overcome the problem of calciner collapse and ensure that production increases to more than 6,100 tons per day.
  • Reduce the actual coal consumption of clinker production by 13 kg/ton and reduce standard coal consumption by more than 10 kg per ton of clinker.
  • Increase the 3-day compressive strength of clinker to more than 30 MPa.

Results of the Rotary Kiln System Upgrade

After the upgrade, the raw meal feed rate increased from 350 t/h to 425 t/h. Based on a material consumption coefficient of 1.61, the system output also climbed from 5200 t/d to 6330 t/d. Furthermore, the C1 outlet temperature dropped by 30°C to 308°C, and the dust collection efficiency at the C1 outlet increased to 94%. Regarding energy consumption, the standard coal consumption for clinker decreased by 16 kg/t to 105 kg/t, while the three-day compressive strength of the clinker increased from 27 MPa to 32 MPa. The CO indicator at the kiln-tail chimney fell from ≥2200 to ≤200 in the comparison table; its measurement unit still needs to be confirmed. It’s worth noting that the system upgrade also optimized nitrogen oxide emission concentration control. When the nitrogen oxide concentration is controlled at 50 mg/m³, ammonia consumption is less than 1 t/h.

In summary, the system upgrade achieved its intended goals, significantly improving clinker yield and quality while significantly reducing production costs. A detailed comparison of the upgrade parameters is shown in Table.

ItemBeforeAfter
Clinker output (t/d)52006330
High-temperature fan speed (r/min)720740
C1 outlet pressure / Pa-4800-4680
Smoke chamber temperature (°C)11001050
Tertiary-air damper opening (%)3160
CO indicator at the kiln-tail chimney (unit not specified)≥2200≤200
Inlet air pressure of the high-temperature fan / Pa-6400-6130
Standard coal consumption (kg/t clinker)121105
C1 outlet temperature / °C338308
Exit pressure of the decomposition furnace / Pa-1300-1050
Smoke chamber pressure / Pa-400-330
3D strength of the clinker / MPa2732
C1 dust collection efficiency /%85.494
Firing decomposition rate/%9193

If you want to learn the details of rotary kiln revamp project, or to upgrade your rotary kiln or cement production line, please contact us!